Gaia
GAIA.ASU.SP.ESM.00007
Issue 2.00
Page 38 of 79
Astrium Ltd owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in
whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
GAIA.ASU.SP.ESM.00007 (Avionics SCOE Req Iss 2).doc
AVI-3569/CREATED/T
Measurement of LV Command pulses shall be triggered asynchronously by detection of an incoming
pulse with the following specifications:
Pulse Width > 1ms
Pulse Amplitude > 10.0V
AVI-3570/CREATED/T
LV STATE (OPEN/CLOSE) shall be made available to the RTS.
AVI-3571/GSE-SYS-754/T
It shall be possible to acquire the LV pulses simultaneously on all channels.
3.6.6.2 MPS LV Status Simulation
AVI-3573/CREATED/T
MPS LV Status Simulation function shall be provided by relay simulation (16x) of each LV STATUS
micro-switch.
AVI-3574/CREATED/T
LV Status Simulation shall conform to the following specifications: [AD06] Table 3.5-28 (Relay Status
Acquisition Source Specification).
AVI-3575/CREATED/T
In open-loop test modes LV STATUS (OPEN/CLOSE) relay shall be set to the STATE value of the
corresponding LV command pulse acquisition (see AVI-3560).
AVI-3576/CREATED/T
In open-loop test modes, it shall be possible to overwrite the LV STATUS from the local MMI or from
the CCS (Test Procedure/Command Line).
Note: This allows error injection into the MPE - Latch Valve Status not reflecting the commanded
operation.
AVI-3577/CREATED/T
In closed-loop test mode, LV STATUS shall be defined by the RTS.