APPENDIX AVI212 Especificações Página 39

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 79
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 38
Gaia
GAIA.ASU.SP.ESM.00007
Issue 2.00
Page 39 of 79
Astrium Ltd owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in
whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
GAIA.ASU.SP.ESM.00007 (Avionics SCOE Req Iss 2).doc
3.6.6.3 MPS FCV Command Pulse Acquisition
AVI-3579/GSE-SYS-740/T
The MPS FCV Command Pulse Acquisition interface shall be provided by fixed loads (16x) simulating
each of the FCV coils.
AVI-3580/GSE-SYS-740/T
The FCV Command Acquisition interface shall conform to the following specifications: [AD06] Table
3.5-36 (Flow Control Valve Interface Specification - Receiver Circuit Specification).
AVI-3581/GSE-SYS-740/T
FCV Command Pulse Acquisition shall provide measurements of the integrated ON time for each
FCV, the individual command pulse widths and an event count per FCV, as detailed below:
EVENT COUNT limit 65536
ON time resolution 5 %
Pulse WIDTH resolution
100.0 µs - for pulse widths 5ms to continuous
Table 3.6-5: CPS - FCV Command Pulse Measurement Specification
AVI-3593/CREATED/T
Once an FCV Command has triggered, ON time measurements shall be integrated every 15.625 ms
(equivalent to the RTS Simulation Cycle rate of 1/64 of the Major Frame rate) and calculated as
percentage (ON) over the integration period. TBC
Note: Although the CPS Model in the RTS executes at 64Hz in real-time, thrust vectors output to the
Dynamics Model need to consider thruster pulses to an accuracy of <1ms.
AVI-3595/CREATED/T
Measurement of LV Command pulses shall be triggered asynchronously by detection of an incoming
pulse with the following specifications:
Pulse Width > 1ms
Pulse Amplitude > 10.0V
AVI-3596/CREATED/T
It shall be possible to reset the event counters, individually or all at once, by command from the local
MMI or from the CCS (Test Procedure/Command Line)..
AVI-3597/GSE-SYS-740/T
FCV ON times shall be made available to the RTS for closed-loop testing.
AVI-3598/GSE-SYS-756/T
It shall be possible to acquire the FCV pulses simultaneously on all channels.
Vista de página 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 78 79

Comentários a estes Manuais

Sem comentários